MANY BENEFITS OF TURBOCOLLECTOR
TURBULENT FLOWS AT SIGNIFICANTLY LOWER FLOW RATES
Turbulent flow increases the heat transfer to the collector fluid. With the TurboCollector, turbulent flow is induced at 22% lower flow rates than a conventional collector (1,800 Reynolds vs 2,300 for conventional collectors)
UP TO 11% INCREASE IN COP
Simulations show the TurboCollector reduces the convective resistance with up to 80%, increasing the collector fluid temperature and COP of the heat pump
ELECTRICITY SAVINGS, YEAR AFTER YEAR
During 50+ years of collector lifetime, the TurboCollector will continuously reduce electricity consumption, saving money and CO2
CERTIFIED PRODUCTS
The TurboCollector comes with all relevant approvals, depending on your local market (P-marking and SKZ)
AVAILABLE IN ALL RELEVANT DIMENSIONS AND PRESSURE CLASSES
Single or double collectors, 25mm, 32mm, 40mm, 45mm, 50mm and 55mm. Also available in MuoviTech's patent pending elliptical turbo design: MuoviEllipse
MAXIMISES THE HEAT TRANSFER
Muovitech's fins with alternating pattern maximises the heat transfer by initiating turbulent flows at lower flow rates than conventional collectors
SEE THE FULL MOVIE - Turn up the volume
MUOVITECH'S PATENTED FIN DESIGN IS OPTIMISED FOR IMPROVING HEAT TRANSFER AND GEOTHERMAL SYSTEM EFFICIENCY

Clockwise and counterclockwise rotation
Independent research shows that MuoviTech's unique and patented fin design with alternating fin directions is creating the most optimal heat transfer.
Up to 600% increase in convective heat transfer
There is a negligible pressure drop difference between the TurboCollector and laminar probes for flow rates outside of Reynolds numbers 1800 to 2300.
Study made in cooperation with Chalmers University in Sweden
The study concludes that MuoviTech's Turbo Collector creates up to 600% increase in convective heat transfer.
TO THE STUDY
PRODUCT INFORMATION FOR TURBOCOLLECTOR®
TurboCollector®
Energy collector with better performance.

BETTER PERFORMANCE
TurboCollector is a patented development of a traditional collector, with significantly better heat transfer characteristics. This is created by a more turbulent flow. Field measurements show that TurboCollector has up to 33% lower bore resistance than equivalent measurements on a smooth collector.
Read about 3 independent tests of TurboCollector®
PRODUCT INFORMATION
Dimensions: 32mm, 40mm, 45mm, 50mm
Lengths: 50-500mtr
Pressure classes: PN10 SDR17, PN12.5 SDR13.6 and PN16 SDR11
Material: PE100 and PE100RC
Supplied with factory-customized return weight. The return bend is well protected. Length is adapted for optimal transport and easy installation.
CERTIFICATE
P-mark of RISE with approval number SC1106-11.